Factory FM200 Manifold Fire Suppression System for Fire Fighting

Factory FM200 Manifold Fire Suppression System for Fire Fighting

hfc-227ea finds use in fire suppression systems in data processing and telecommunication facilities, and in protection of many flammable liquids and gases. hfc-227ea falls in the category of Clean Agents and is governed by NFPA 2001 - Standard for Clean Agent Fire Extinguishing Systems.
Send Inquiry
Description
We hope to use our efforts to provide you with meticulous care. In the field of Fluorine Gas, Clean Agent Gas, Hfc227ea, we will persist in continuous and endless pursuit of improvement and optimization. We are willing to be your loyal partner and trustworthy friend! We will continue to carry forward the enterprise spirit of 'unity, diligence, efficiency, and innovation', adhere to the marketing strategy of 'quality-oriented, honesty first', and strive to create a more brilliant tomorrow. We are committed to the in-depth development of customer needs and services, as well as collaborate with the industry to effectively enhance the overall competitiveness and create value. In pursuit of excellence, we are striding forward with robust momentum and writing the new chapter for the industry.

Introduction:

hfc-227ea finds use in fire suppression systems in data processing and telecommunication facilities, and in protection of many flammable liquids and gases. hfc-227ea falls in the category of Clean Agents and is governed by NFPA 2001 - Standard for Clean Agent Fire Extinguishing Systems. Effective fire suppression requires introducing a concentration of the hfc-227ea agent between 6.25% and 9% depending on the hazard being suppressed. Its NOAEL for cardiac sensitization is 9%. The United States Environmental Protection Agency allows concentration of 9% volume in occupied spaces without mandated egress time, or up to 10.5% for a limited time. Most fire suppression systems are designed to provide concentration of 6.25-9%.


The HFC-227ea fire suppression agent was the first non-ozone-depleting replacement for Halon 1301. In addition, HFC-227ea leaves no residue on valuable equipment after discharge.


HFC-227ea contains no chlorine or bromine atoms, presenting no ozone depletion effect. Its atmospheric lifetime is approximated between 31 and 42 years. It leaves no residue or oily deposits and can be removed by ventilation of the affected space.


As an aerosol propellant, HFC-227ea is used in pharmaceutical metered dose inhalers such as those used for dispensing asthma medication.


Physical properties:

Property


Chemical Name

1,1,1,2,3,3,3-Heptafluoropropane

Chemical Formula

CF3CHFCF3

Molecular Weight

170.03

Boiling Point, 1 atm, °C (°F)

–16.34 (2.59)

Freezing Point, °C (°F)

–131 (–204)

Critical Temperature, °C (°F)

101.75 (215.1)

Critical Pressure, kPa (psia)

2925.0 (424.24)

Critical Density, kg/m3 (lb/ft3)

594.25 (37.098)

Liquid Density at 25 °C (77 °F), kg/m3 (lb/ft3)

1387.7 (86.63)

Density, Saturated Vapor at Boiling Point, kg/m3 (lb/ft3)

8.4860 (0.52979)

Vapor Density at 25 °C (77 °F) and 1 atm

7.1461 (0.4461)

Specific Heat, Liquid (cP) at 25 °C (77 °F), kJ/kg-°C (Btu/lb°F)

1.1816 (0.28242)

Specific Heat, Vapor (cP) at 25 °C (77 °F), kJ/kg-°C (Btu/lb°F) and 1 atm

0.81327 (0.81327)

Vapor Pressure, Saturated at 25 °C (77 °F), kPa (psia)

454.73 (65.9)

Heat of Vaporization at BP, kJ/kg (Btu/lb)

131.77 (56.7)

Thermal Conductivity, Liquid at 25 °C (77 °F), W/m–°C (Btu/hr-ft°F)

0.060491 (0.034975)

Thermal Conductivity, Vapor at 1 atm, W/m-°C (Btu/hr-ft°F)

0.013336 (0.0077103)

Viscosity, Liquid at 25 °C (77 °F), cP (lb/ft-hr)

0.23935 (0.57901)

Viscosity, Vapor at 1 atm, cP (lb/ft-hr)

0.011590 (0.028038)

Relative Dielectric Strength at 1 atm, 25 °C (77 °F) (N2=1)

2.00

Solubility of Water in FM-200™ at 20 °C (68 °F), ppm

600

Ozone Depletion Potential, ODP

0.0 (CFC-11 = 1)

Global Warming Potential, GWP (100 yr ITH. For CO2, GWP = 1)

3220

Atmospheric Lifetime, yr

34.2

TSCA Inventory Status

Reported/Included

European List of New Chemical Substances

EINECS, Listed (207-079-2)


Certificate:

UL listed and REACH registered


Applications:

• Air traffic control centers

• Data centers and server rooms

• Telecommunication networks

• Electric utilities

• Financial networks

• Medical equipment

• Museums and libraries

• Marine vessels


FAQ

Quick response

All requests will be replied within 12 hours.

 

How long i can get the feedback after we sent the enquiry?

We will reply you within 12 hours in working day. 

  

What's the universal lead-time for order delivery?

Small production: 3-4 days Mass production :7-15days or basing on your qty.


Hot Tags: HFC227, China, suppliers, manufacturers, in stock, made in China, Fm Fire Protection, Fire Protection Gas, Fire Suppression, Electronic Components Cleaning, Passive Fire Protection, Noah7300

Technical Parameters
We will use the great nation's ingenuity to cast high-quality Factory FM200 Manifold Fire Suppression System for Fire Fighting and provide thoughtful services with our responsibilities. We take 'integrity, friendliness, responsibility, awe' as our core values. With high-quality products and excellent services, we have had a happy cooperation with many customers at home and abroad. We cultivate the sense of participation of all employees, care about the material and spiritual needs of employees.