hfc-227ea finds use in fire suppression systems in data processing and telecommunication facilities, and in protection of many flammable liquids and gases. hfc-227ea falls in the category of Clean Agents and is governed by NFPA 2001 - Standard for Clean Agent Fire Extinguishing Systems.
Send Inquiry
Description
Our complete service and sales system is located around the world to meet the needs of our customers and to provide them with high quality Fire Protection Fluid, Nfpa 2001 Clean Agent, 227 Gas and value-added services. Adhering to the business philosophy of 'customer first, forge ahead', our company has established long-term and stable cooperative relations with many global customers, and provides our them with the best quality service. We strictly implement the production standards and pay attention to product quality. At the same time, our company also actively communicates with customers to understand the needs of customers, recognize our shortcomings and provide professional and timely after-sales service for customers.

Introduction:

hfc-227ea finds use in fire suppression systems in data processing and telecommunication facilities, and in protection of many flammable liquids and gases. hfc-227ea falls in the category of Clean Agents and is governed by NFPA 2001 - Standard for Clean Agent Fire Extinguishing Systems. Effective fire suppression requires introducing a concentration of the hfc-227ea agent between 6.25% and 9% depending on the hazard being suppressed. Its NOAEL for cardiac sensitization is 9%. The United States Environmental Protection Agency allows concentration of 9% volume in occupied spaces without mandated egress time, or up to 10.5% for a limited time. Most fire suppression systems are designed to provide concentration of 6.25-9%.


The HFC-227ea fire suppression agent was the first non-ozone-depleting replacement for Halon 1301. In addition, HFC-227ea leaves no residue on valuable equipment after discharge.


HFC-227ea contains no chlorine or bromine atoms, presenting no ozone depletion effect. Its atmospheric lifetime is approximated between 31 and 42 years. It leaves no residue or oily deposits and can be removed by ventilation of the affected space.


As an aerosol propellant, HFC-227ea is used in pharmaceutical metered dose inhalers such as those used for dispensing asthma medication.


Physical properties:

Property


Chemical Name

1,1,1,2,3,3,3-Heptafluoropropane

Chemical Formula

CF3CHFCF3

Molecular Weight

170.03

Boiling Point, 1 atm, °C (°F)

–16.34 (2.59)

Freezing Point, °C (°F)

–131 (–204)

Critical Temperature, °C (°F)

101.75 (215.1)

Critical Pressure, kPa (psia)

2925.0 (424.24)

Critical Density, kg/m3 (lb/ft3)

594.25 (37.098)

Liquid Density at 25 °C (77 °F), kg/m3 (lb/ft3)

1387.7 (86.63)

Density, Saturated Vapor at Boiling Point, kg/m3 (lb/ft3)

8.4860 (0.52979)

Vapor Density at 25 °C (77 °F) and 1 atm

7.1461 (0.4461)

Specific Heat, Liquid (cP) at 25 °C (77 °F), kJ/kg-°C (Btu/lb°F)

1.1816 (0.28242)

Specific Heat, Vapor (cP) at 25 °C (77 °F), kJ/kg-°C (Btu/lb°F) and 1 atm

0.81327 (0.81327)

Vapor Pressure, Saturated at 25 °C (77 °F), kPa (psia)

454.73 (65.9)

Heat of Vaporization at BP, kJ/kg (Btu/lb)

131.77 (56.7)

Thermal Conductivity, Liquid at 25 °C (77 °F), W/m–°C (Btu/hr-ft°F)

0.060491 (0.034975)

Thermal Conductivity, Vapor at 1 atm, W/m-°C (Btu/hr-ft°F)

0.013336 (0.0077103)

Viscosity, Liquid at 25 °C (77 °F), cP (lb/ft-hr)

0.23935 (0.57901)

Viscosity, Vapor at 1 atm, cP (lb/ft-hr)

0.011590 (0.028038)

Relative Dielectric Strength at 1 atm, 25 °C (77 °F) (N2=1)

2.00

Solubility of Water in FM-200™ at 20 °C (68 °F), ppm

600

Ozone Depletion Potential, ODP

0.0 (CFC-11 = 1)

Global Warming Potential, GWP (100 yr ITH. For CO2, GWP = 1)

3220

Atmospheric Lifetime, yr

34.2

TSCA Inventory Status

Reported/Included

European List of New Chemical Substances

EINECS, Listed (207-079-2)


Certificate:

UL listed and REACH registered


Applications:

• Air traffic control centers

• Data centers and server rooms

• Telecommunication networks

• Electric utilities

• Financial networks

• Medical equipment

• Museums and libraries

• Marine vessels


FAQ

Quick response

All requests will be replied within 12 hours.

 

How long i can get the feedback after we sent the enquiry?

We will reply you within 12 hours in working day. 

  

What's the universal lead-time for order delivery?

Small production: 3-4 days Mass production :7-15days or basing on your qty.


Hot Tags: HFC227, China, suppliers, manufacturers, in stock, made in China, Hfc227ea, FM Approved FK5112, Safe Fire Protection, Liquid Cooling Coolant, Hydrofluoroether, Extinguishant

Technical Parameters
Our success counts on building trusted, long-term client relationships, and focus on delivering first-class products and cost control. To make professional and advanced Fire Trace Automatic Extinguishing Device (CO2 OR HFC227), we're committed to adhering to the strictest standards during manufacturing process. Our company has an experienced service team to provide customers with thoughtful service. Our insistence on science and technology innovation has provided strong scientific and technological support for the construction of a world class enterprise with global competitiveness.